The iPandaSys SmartIAQ is one of the Smart IoT features to iPandaSys can work on the local Wi-Fi network with the MQTT protocol which is used in a wide variety of industries, such as automotive, manufacturing, telecommunications, oil and gas, etc. Combining with iPandaSys Server, the SmartIAQ can connect to other Systems with most of the contemporary protocol such as OPC UA / BACNet / Modbus / LoRaWan / MQTT / NB-IoT.
Further connect the local network to the broadband internet services, all connected sensors can link up with the iPandaSys Cloud service and customers can have an easy and secure way to control, monitor and perform data analysis to their facilities in anywhere in the world with internet access.
technical data
Essentials
Detection Method
Air detection
Ratings
supply voltage
DC 9~24V, it is recommended to use DC 12V, 1A power adapter
Product
power consumption
DC12V, <140 mA (WIFI function turned on) <100mA (WIFI function turned off)
Environment Conditions
Working
environment
Temperature range -20~80°C, Humidity range 0~100%RH (non-condensing) TVOC and E-CO2 can only work normally in the range of 0~50°C and cannot be guaranteed in other temperature ranges TVOC and E-CO2 sensors work normally
Air Temperature
measurement range
0°C to 85°C
Measurement
accuracy
±1°C
Precision
1°C
Air Humidity
measurement range
0~100RH%
MEASUREMENT ACCURACY
±7RH%
Precision
0.1%RH
PM2.5
measurement range
0~500ug/ m³
MEASUREMENT ACCURACY
Under 100~500ug/m³, ±10% under 0~100ug/m³, ±10ug
Precision
1ug/m³
CO2
measurement range
0~2000ppm
MEASUREMENT ACCURACY
±10% (measured after 24 hours in an airtight, uniformly distributed environment)
Precision
1ppm
WARM-UP TIME
Around 5 minutes. During this time, E-CO2 outputs 450ppm, the value remains unchanged. After the heat is over, the value changes with the environment.
TVOC
measurement range
125-600ppb
MEASUREMENT ACCURACY
±10% (measured after 24 hours in an airtight, uniformly distributed environment)
Precision
1ppb
WARM-UP TIME
Around 5 minutes. During this time, TVOC outputs 125ppb. The value remains unchanged. After the heat is over, the value changes with the environment.
HCHO
measurement range
0-2000ppb
MEASUREMENT ACCURACY
The service life in the air is about 3 years. If not in use, please store it in a 0~20°C environment
Precision
1ppb
LED color description - Blue
LIGHT COLOR
Blue
INSTRUCTION OF LIGHT
0 < PM2.5 < 75
AIR QUALITY
Good
LED color description - Green
LIGHT COLOR
Green
INSTRUCTION OF LIGHT
75 ≤ PM2.5 < 150
AIR QUALITY
Medium
LED color description - Red
LIGHT COLOR
Red
INSTRUCTION OF LIGHT
PM2.5 ≥ 150
AIR QUALITY
Poor
ordering Information
Model: iPandaSys IAQ
Order number : iPS-IoT-SmartIAQ
Wifi IAQ, Air Temperature, Air Humidity, PM2.5, CO2, TVOC and HCHO Detection Sensor
Structure and installation
Installation Notes:
1. Locate three screw holes on the wall and install the base.
2. Rotate the main part to the base according to the instructions in the figure to complete the installation.